Vita Spas designed the industry’s first hot tub that was built to be appliance grade. They also utilize a steel frame as one of the essential building blocks for each of their products. Their focus on wellness and hydrotherapy includes the same level of therapeutic relief that consumers would receive by visiting a massage therapist.
This company’s products offer consumers the choice between multiple different jets and configurations in order to give them the desired results, ranging from relaxation to a therapeutic massage. The massage techniques that are emulated by the specific jets that a consumer chooses include reflexology, sports massage, classic massage, effleurage massage and shiatsu massage.
The Cover Guy provides all Vita Spa replacement covers so you are guaranteed a perfect fit every time.
Vita Spas Models:
- Series 700
- 500 Series
- Series 300
- Series 100
- XSR Swim Spa
- XSP Swim Spa
- XSD Swim Spa
- XS1 Swim Spa
- XB4 Swim Spa
- XL4 Swim Spa
These are the error codes and display messages that a ThermoSpas Hot Tub may display, along with what they mean and any actions required:
Vita Spas Error Messages
Message | Meaning | Action Required |
---|---|---|
OHH | Stands for "Overheat", and the tub shuts down. One of the sensors detected temperatures of 118°F (47.8°C) at the location of the heater. Spa heater shuts down automatically until temp falls below 108°F (42°C).Could indicate a pump operating at low speed for an extended time, constant filtering due to a programming error or a faulty pump. |
DO NOT GET INTO THE WATER! Take off the heat shield cover to allow the water to cool down. Make sure that the slice valves are open and reprogram the spa to make sure there are no overlapping time cycles. Open all jets. Contact the dealer or service organization if the problem continues. |
OHS | Overheating condition where a water temperature sensor has detected water temperatures of 110°F (43.3°C). Spa functioning is then disabled until temps fall below 108°F (42.2°C).Could indicate a pump operating at low speed for an extended time, constant filtering due to a programming error or a faulty pump. |
DO NOT GET INTO THE WATER! Take off the heat shield cover to allow the water to cool down. Make sure that the slice valves are open and reprogram the spa to make sure there are no overlapping time cycles. Open all jets. Contact the dealer or service organization if the problem continues. |
ICE | Sensor detects possible freeze conditions. | Heater powers on to ensure water temperatures stay above 45°F (7.2°C). |
HFL | Heater flow problem possibly caused by low water or plugged up filters. The heater shuts down while other functions of spa continue to operate normally. | You can add water, remove and clean filter if it’s dirty and open all jets to resume normal operation. If the problem persists, contact the dealer or service organization. |
LF | Means low flow problems are persistent. This error code will display the fifth time that the “HFL” message occurs within 24 hours.With this error, the heater will shut down, but other functions of the hot tub will continue to operate normally. Issue is possibly caused by low water or a plugged filter. | You can add water, remove and clean filter if it’s dirty and open all jets to resume normal operation. If the problem persists, contact the dealer or service organization. |
drY | Sensors detect lack of water to the heater. Heater will shut down, but other function of the spa will continue to operate normally. Issue is possibly caused by closed slice valve or blocked suction return/skimmer/filter. | Remove the blockage, add water or open any closed jets and valves. If the problem persists, contact the dealer or service organization. |
dr | Sensors detect lack of water to the heater. Heater will shut down, but other function of the spa will continue to operate normally.Issue is possibly caused by closed slice valve or blocked suction return/skimmer/filter. Issue is possibly caused by closed slice valve or blocked suction return/skimmer/filter. | Remove the blockage, add water or open any closed jets and valves. |
SnT | Malfunctioning Heater Sensor A. | Contact dealer to get identical replacement Sensor A. |
SnH | Malfunctioning Heater Sensor B. | Contact dealer to get identical replacement Sensor B. |
SnS | Heater Sensors are not in balance. | Contact dealer or service organization for repair. |
Pr -OR- RUN / Priming modePMPS / PURG / AIR / – | Priming Mode | Spa is functioning normally for Priming Mode. |
SLP | Sleep Mode | Spa is functioning normally in Sleep Mode. |
ECN | Economy Mode | Spa is functioning normally in Economy Mode. |
— | Spa water temperature | Current water temperature is not known or measured. |
WATER TOO HOT | Temperature for spa water |
DO NOT GET INTO THE WATER! Water temperatures are too hot and spa operations are disabled. |